Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Level
- Screwdrivers (flat and Phillips)
- Adjustable wrench
- Tape measure
- Vacuum pump and gauge manifold
Step-by-Step Installation
- Choose Installation Location: Select a location with proper wall support, away from direct sunlight and heat sources, with adequate clearance for airflow.
- Mount Indoor Unit: Install mounting plate securely on wall, ensuring it is level. Hang indoor unit on mounting plate.
- Install Outdoor Unit: Place outdoor unit on stable, level surface with proper vibration pads. Ensure adequate clearance for airflow and maintenance.
- Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units using proper flaring tools and torque wrenches.
- Electrical Connection: Connect to properly grounded electrical outlet according to local electrical codes. Use dedicated circuit.
- Vacuum and Charge System: Evacuate system using vacuum pump, then charge with specified refrigerant amount.
- Test Operation: Run system through complete cooling and heating cycles to check for proper operation and refrigerant leaks.
Specifications
Model Series | AS24UQF |
Type | Split System Air Conditioner |
Color | White / Silver |
Cooling Capacity | 24,000 BTU/h |
Heating Capacity | 26,000 BTU/h |
Noise Level (Indoor) | 19 dB (Quietest) - 42 dB |
Control Type | Touch Controls with LED Display + ThinQ App |
Energy Rating | A+++ (Most Efficient) |
Power Requirements | 230V, 50Hz, 15A |
Refrigerant | R32 (Eco-friendly) |
Dimensions Indoor (HxWxD) | 29 x 89 x 21 cm |
Dimensions Outdoor (HxWxD) | 55 x 79 x 29 cm |
Weight Indoor/Outdoor | 9 kg / 32 kg |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 10 years on Dual Inverter Compressor
- Additional Coverage: Optional extended warranty available
For warranty service, contact LG Customer Service at 1-800-243-0000 or visit LG.com
Key Features
Dual Inverter Compressor
LG's advanced Dual Inverter compressor provides precise temperature control, faster cooling/heating, and up to 70% energy savings compared to conventional compressors.
ThinQ Smart Technology
Wi-Fi enabled for complete control via smartphone app, allowing remote operation, energy monitoring, voice control compatibility, and smart diagnosis.
4-Step Filtration System
Multi-stage filtration including anti-bacterial coating, deodorization filter, and fine dust filter to provide clean, healthy air throughout your space.
Quiet Operation
Advanced noise reduction technology ensures whisper-quiet operation as low as 19 dB, quieter than a library whisper.
Auto Clean Function
Automatically dries the indoor unit after use to prevent mold and bacteria growth, maintaining optimal air quality and unit hygiene.
Smart Diagnosis
Automatically detects operational issues and provides troubleshooting guidance through the ThinQ app, simplifying maintenance.
Operating Modes
Cooling Mode
Standard cooling operation with adjustable temperature from 16°C to 30°C
Heating Mode
Efficient heating operation with temperature range from 16°C to 30°C
Dry Mode
Dehumidification function to reduce humidity while maintaining comfortable temperature
Fan Mode
Air circulation only with multiple fan speed options
Auto Mode
Automatic selection of cooling or heating based on room temperature
Energy Saver
Optimizes operation to minimize energy consumption while maintaining comfort
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
Unit not starting | Power issue, remote control batteries dead, circuit breaker tripped | Check power supply, replace remote batteries, reset circuit breaker |
Poor cooling/heating | Dirty filters, blocked airflow, refrigerant leak | Clean filters, ensure proper airflow, contact service technician |
Water leaking indoors | Clogged drain pipe, improper installation | Clear drain pipe, ensure proper installation slope |
Unusual noises | Loose parts, debris in fan, compressor issues | Check for loose components, clean unit, contact service |
Frozen coils | Dirty filters, low refrigerant, restricted airflow | Clean filters, check airflow, contact service for refrigerant check |
Remote not working | Dead batteries, signal obstruction, remote damage | Replace batteries, ensure line of sight, check remote function |
Error Codes
- CH/OJ: Communication error - Check wiring between indoor and outdoor units
- E1/E2: Temperature sensor error - Contact service center
- F1/F2: Indoor fan motor error - Check fan operation and wiring
- P1/P4: High/Low pressure error - Contact service technician
- U4: System communication error - Check power supply and connections
- AC: Power supply error - Check electrical connections and voltage
Manual Downloads
Current Model Manuals
AS24UQF
24,000 BTU Dual Inverter AC
AS18UQF
18,000 BTU Dual Inverter AC
AS12UQF
12,000 BTU Dual Inverter AC
AS09UQF
9,000 BTU Dual Inverter AC
Popular Previous Models
AS24HQV
24,000 BTU ThinQ AC
AS18BQV
18,000 BTU Standard AC
AS12HQV
12,000 BTU ThinQ AC
AS09BQV
9,000 BTU Standard AC