Installation Guide
Tools Needed:
- Multimeter
- Service toolkit
- Refrigerant gauges
- Vacuum pump
- Leak detector
Step-by-Step Installation
- Site Preparation: Ensure proper clearance and ventilation for optimal performance and service access.
- Electrical Connection: Verify voltage requirements and connect to appropriate power supply with proper grounding.
- Refrigerant Lines: Install and connect refrigerant lines following manufacturer specifications.
- Drainage System: Set up proper drainage with correct slope and routing.
- Control Wiring: Connect control wiring according to wiring diagram specifications.
- System Check: Perform pre-startup checks including electrical safety and component verification.
- Commissioning: Start system and verify proper operation across all modes and functions.
Specifications
Model Series | Inverter V Series |
Type | Variable Speed Inverter System |
Compressor Type | Digital Scroll Inverter |
Cooling Capacity | 24,000 - 60,000 BTU/h |
Heating Capacity | 26,000 - 62,000 BTU/h |
Power Requirements | 208-230V, 60Hz, 1-3 Phase |
Refrigerant Type | R410A |
Operating Range | -13°F to 115°F |
Sound Level | 19-45 dB |
Dimensions | Varies by model |
Weight | 150-300 lbs |
Efficiency Rating | SEER 20+ |
Warranty Information
- Compressor Warranty: 10 years parts
- Parts Warranty: 5 years
- Labor Warranty: 1 year
- Additional Coverage: Optional extended service plans available
For warranty service, contact LG Customer Service at 1-800-243-0000 or visit LG.com
Key Features
Dual Inverter Compressor
Advanced dual rotary inverter compressor provides precise temperature control, reduced noise, and increased energy efficiency with enhanced durability.
Smart Diagnosis
Built-in smart diagnosis system helps technicians quickly identify and troubleshoot issues using mobile app connectivity and error code analysis.
Variable Speed Operation
Intelligent variable speed technology adjusts compressor and fan speeds to maintain consistent temperatures while minimizing energy consumption.
Gold Fin™ Anti-Corrosion
Golden anti-corrosion treatment on heat exchanger fins provides superior protection against harsh environmental conditions and extends system life.
Wi-Fi Connectivity
SmartThinQ enabled for remote monitoring, control, and diagnostics through smartphone applications and web interfaces.
Quiet Operation
Advanced noise reduction technology including sound-absorbing materials and vibration isolation for ultra-quiet performance.
Service Features Explained
Self-Diagnosis
Automated system checks and error reporting for quick fault identification
Service Mode
Dedicated service mode for testing components and system functions
Data Logging
Comprehensive operation data recording for performance analysis
Remote Access
Remote system monitoring and control capabilities for service technicians
Component Testing
Individual component test functions for precise diagnostics
Software Updates
Field-upgradable firmware for system improvements and bug fixes
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
System not starting | Power supply issue, control board failure | Check power supply, verify control board operation |
Poor cooling/heating | Refrigerant leak, dirty filters, compressor issue | Check refrigerant levels, clean filters, inspect compressor |
Unusual noises | Fan motor issues, loose components, compressor problems | Inspect fan assembly, tighten components, check compressor |
Water leakage | Clogged drain line, improper installation | Clear drain line, verify proper installation slope |
Error codes displayed | Sensor failure, communication errors, component faults | Refer to error code manual, check sensors and wiring |
High power consumption | Dirty coils, refrigerant issues, mechanical problems | Clean heat exchangers, check refrigerant charge, inspect mechanical components |
Common Error Codes
- CH 00: Communication error - Check wiring and connections
- CH 01: Indoor unit error - Inspect indoor PCB and sensors
- CH 02: Outdoor unit error - Check outdoor PCB and components
- CH 03: Compressor error - Verify compressor operation and wiring
- CH 04: Fan motor error - Inspect fan motors and drivers
- CH 05: Sensor error - Check temperature and pressure sensors
Manual Downloads
Current Model Manuals
LVN240HSV4
24k BTU Inverter V System
LVN360HSV4
36k BTU Inverter V System
LVN480HSV4
48k BTU Inverter V System
LVN600HSV4
60k BTU Inverter V System
Previous Models
LVN180HSV3
18k BTU Inverter System
LVN240HSV3
24k BTU Inverter System
LVN300HSV3
30k BTU Inverter System
LVN480HSV3
48k BTU Inverter System